Microtronix Access User Guide
Acknowledgment Hold Back Timeout (T2 Timer): The length in seconds before packet
acknowledgments (RR) are sent.
Restart Request Timeout (T10/T20 Timer): The length in seconds before an outbound restart
request is retransmitted. Canceled once a restart confirmation is received.
Call Request Timeout (T11/T21 Timer): The length in seconds started when a call request is
transmitted. Canceled when a call accept or clear request is received. Upon expiry, a clear
request will be transmitted.
Reset Request Timeout (T12/T22 Timer): The length in seconds started when a reset request
is transmitted. Canceled when a reset request or reset confirm is received. Upon expiry, a clear
request (SVC) or reset request (PVC) will be transmitted.
Clear Request Timeout (T13/T23 Timer): The length in seconds, started when a clear request
is transmitted. Canceled when a clear request or clear confirm is received. Upon expiry, a
diagnostic packet will be transmitted (DCE) or a clear request will be re-transmitted (DTE).