Mindray uMEC10 User Manual

Mindray uMEC10
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
6
12 Monitoring NIBP .......................................................................................................... 12-1
12.1 Introduction ............................................................................................................. 12-1
12.2 Safety ...................................................................................................................... 12-2
12.3 Measurement Limitations ........................................................................................ 12-2
12.4 Measurement Methods ............................................................................................ 12-3
12.5 Setting Up the NIBP Measurement ......................................................................... 12-3
12.5.1 Preparing the Patient ...................................................................................... 12-3
12.5.2 Preparing to Measure NIBP ........................................................................... 12-3
12.5.3 Starting and Stopping Measurements ............................................................. 12-4
12.5.4 Correcting the Measurement if Limb is not at Heart Level ............................ 12-4
12.5.5 Enabling NIBP Auto Cycling and Setting the Interval ................................... 12-5
12.5.6 Starting a STAT Measurement ........................................................................ 12-5
12.6 Understanding the NIBP Numerics ......................................................................... 12-6
12.7 Making NIBP Analysis ............................................................................................ 12-7
12.8 Changing NIBP Settings ......................................................................................... 12-7
12.8.1 Setting the Initial Cuff Inflation Pressure ....................................................... 12-7
12.8.2 Setting NIBP Alarm Properties ...................................................................... 12-8
12.8.3 Displaying NIBP List ..................................................................................... 12-8
12.8.4 Setting the Pressure Unit ................................................................................ 12-8
12.8.5 Switching On NIBP End Tone........................................................................ 12-8
13 Monitoring Temp .......................................................................................................... 13-1
13.1 Introduction ............................................................................................................. 13-1
13.2 Safety ...................................................................................................................... 13-1
13.3 Making a Temp Measurement ................................................................................. 13-1
13.4 Understanding the Temp Display ............................................................................ 13-2
13.5 Setting the Temperature Unit .................................................................................. 13-2
14 Monitoring IBP (for uMEC12/uMEC15) ................................................................... 14-1
14.1 Introduction ............................................................................................................. 14-1
14.2 Safety ...................................................................................................................... 14-1
14.3 Zeroing the Transducer ........................................................................................... 14-2
14.4 Setting Up the Pressure Measurement .................................................................... 14-3
14.5 Understanding the IBP Display ............................................................................... 14-4
14.6 Changing IBP Settings ............................................................................................ 14-5
14.6.1 Changing a Pressure for Monitoring .............................................................. 14-5
14.6.2 Setting the Pressure Label Order .................................................................... 14-6
14.6.3 Setting Alarm Properties ................................................................................ 14-6
14.6.4 Changing Averaging Time .............................................................................. 14-6
14.6.5 Setting Up the IBP Wave ................................................................................ 14-6
14.6.6 Setting the Pressure Unit ................................................................................ 14-7
14.7 Troubleshooting ...................................................................................................... 14-7
15 Monitoring Cardiac Output (for uMEC12/uMEC15) .............................................. 15-1

Table of Contents

Other manuals for Mindray uMEC10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray uMEC10 and is the answer not in the manual?

Mindray uMEC10 Specifications

General IconGeneral
Resolution800 x 600
ECG3/5-lead ECG
EtCO2Optional
BatteryRechargeable lithium-ion
Battery Life4 hours
Dimensions110 mm
AlarmAudible and visual alarms
Power SupplyAC 100-240V, 50/60Hz
AgentNo
O2No