EasyManua.ls Logo

Mitsubishi Electric RD77MS2 - Page 112

Mitsubishi Electric RD77MS2
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
110
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
Current feed value
The following table shows the "[Md.20] Current feed value" during speed control corresponding to the "[Pr.21] Current feed
value during speed control" settings. (However, the parameters use the set value of the reference axis.)
Restrictions
Set "Positioning complete" in "[Da.1] Operation pattern". The error "Continuous path control not possible" (error code:
1A1EH to 1A20H) will occur and the operation cannot start if "continuous positioning control" or "continuous path control" is
set in "[Da.1] Operation pattern". ("Continuous positioning control" and "continuous path control" cannot be set in speed
control.)
Set the WITH mode in the output timing when using an M code. The M code will not be output, and the M code ON signal
will not turn ON if the AFTER mode is set.
The error "No command speed" (error code: 1A12H to 1A14H) will occur if the current speed (-1) is set in "[Da.8] Command
speed".
Set "1: Reference axis speed" in "[Pr.20] Interpolation speed designation method". If "0: Composite speed" is set, the error
"Interpolation mode error" (Error code: 199AH) occurs and the positioning will not start.
The software stroke limit check is not carried out if the control unit is set to "degree".
Restriction for the speed limit value
When either of control axes (1 to 4 axes) exceeds the speed limit, that axis is controlled with the speed limit value. The
speeds of the other axes are limited at the ratios of "[Da.8] Command speed".
Ex.
When the axis 1 and the axis 2 are used
With the settings shown above, the operation speed in speed control is as follows.
Axis 1: 4000.00 mm/min (Speed is limited by [Pr.8].)
Axis 2: 3000.00 mm/min (Speed is limited at a ratio of an axis 1 command speed to an axis 2 command speed.)
Operation runs at speed 1 when a reference axis speed is less than 1 as a result of speed limit. In addition, when the bias
speed is set, the set value will be the minimum speed.
"[Pr.21] Current feed value during speed control" setting [Md.20] Current feed value
0: Do not update current feed value The current feed value at speed control start is maintained.
1: Update current feed value The current feed value is updated.
2: Zero clear current feed value The current feed value is fixed at 0.
Setting item Axis 1 setting Axis 2 setting
[Pr.8] Speed limit value 4000.00 mm/min 5000.00 mm/min
[Da.8] Command speed 8000.00 mm/min 6000.00 mm/min
V
t
In speed control
Current feed value during speed
control start is maintained
(a) Current feed value not updated
t
t
0
(b) Current feed value updated
(c) Current feed value zero cleared
Current feed value is updated
V
In speed control
In speed control
V

Table of Contents