3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
111
3
Setting positioning data
When using speed control (forward run: speed 1 to 4, reverse run: speed 1 to 4), set the following positioning data.
: Always set, : Set as required, : Setting restricted, : Setting not required
*1 When using 2- to 4-axis speed control, it is necessary to set the axis to be used as the interpolation axis.
*2 Refer to the following for information on the setting details.
Page 445 Positioning Data
Setting item Setting required/not required
for the reference axis
Setting required/not required
for the interpolation axis
[Da.1] Operation pattern 
[Da.2] Control method 
[Da.3] Acceleration time No. 
[Da.4] Deceleration time No. 
[Da.6] Positioning address/movement amount 
[Da.7] Arc address 
[Da.8] Command speed 
[Da.9] Dwell time/JUMP destination positioning data No. 
[Da.10] M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches

[Da.20] Axis to be interpolated No.1
*1
[Da.21] Axis to be interpolated No.2
*1
[Da.22] Axis to be interpolated No.3
*1
[Da.27] M code ON signal output timing 
[Da.28] ABS direction in degrees 
[Da.29] Interpolation speed designation method 