12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
391
12
Axis monitor data [Md.29] Speed-position switching control positioning movement amount 2414+100n
2415+100n
[Md.30] External input signal 2416+100n
[Md.31] Status 2417+100n
[Md.32] Target value 2418+100n
2419+100n
[Md.33] Target speed 2420+100n
2421+100n
[Md.34] Movement amount after near-point dog ON 2424+100n
2425+100n
[Md.35] Torque limit stored value/forward torque limit stored value 2426+100n
[Md.36] Special start data instruction code setting value 2427+100n
[Md.37] Special start data instruction parameter setting value 2428+100n
[Md.38] Start positioning data No. setting value. 2429+100n
[Md.39] In speed limit flag 2430+100n
[Md.40] In speed change processing flag 2431+100n
[Md.41] Special start repetition counter 2432+100n
[Md.42] Control system repetition counter 2433+100n
[Md.43] Start data pointer being executed 2434+100n
[Md.44] Positioning data No. being executed 2435+100n
[Md.45] Block No. being executed 2436+100n
[Md.46] Last executed positioning data No. 2437+100n
[Md.47] Positioning data being executed Positioning identifier 2438+100n
M code 2439+100n
Dwell time 2440+100n
Positioning option 2441+100n
Command speed 2442+100n
2443+100n
Positioning address 2444+100n
2445+100n
Arc address 2446+100n
2447+100n
Axis to be interpolated 2496+100n
2497+100n
[Md.48] Deceleration start flag 2499+100n
[Md.62] Amount of the manual pulser driving carrying over movement 2422+100n
2423+100n
[Md.100] Home position return re-travel value 2448+100n
2449+100n
[Md.101] Real current value 2450+100n
2451+100n
[Md.102] Deviation counter value 2452+100n
2453+100n
[Md.103] Motor rotation speed 2454+100n
2455+100n
[Md.104] Motor current value 2456+100n
[Md.106] Servo amplifier software No. 2464+100n
2465+100n
2466+100n
2467+100n
2468+100n
2469+100n
[Md.107] Parameter error No. 2470+100n
[Md.108] Servo status1 2477+100n
[Md.109] Regenerative load ratio/Optional data monitor output 1 2478+100n
[Md.110] Effective load torque/Optional data monitor output 2 2479+100n
[Md.111] Peak torque ratio/Optional data monitor output 3 2480+100n
Memory area Item Buffer memory address