12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
531
12
[Cd.131] Parameter No. (Setting for servo parameters to be changed)
Set the servo parameter to be changed.
Fetch cycle: At change request
Setting value
Set with a hexadecimal.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 392 Control data
Setting
value
H
Parameter No. setting
01H to 40H
Writing mode
0: Write to RAM
Writing mode
0: Write to RAM
0
Parameter group
0: PA group
1: PB group
2: PC group
3: PD group
4: PE group
5: PF group
9: Po group
A: PS group
B: PL group
MR-J4(W)-B/MR-JE-B
Setting
value
H
Parameter No. setting
01H to 99H
0
Parameter group
0: Group 0
1: Group 1
2: Group 2
3: Group 3
4: Group 4
5: Group 5
6: Group 6
7: Group 7
8: Group 8
9: Group 9
VCII series