19 Display Module(FX3G-5DM)
19.6 Monitor/Test Mode
278
FX3G Series Programmable Controllers
User's Manual - Hardware Edition
4. Counter [C]
*1. When not using it in a program, a setting value is displayed as
"-----".
5. Input [X] / Output [Y] / Auxiliary Relay [M] / State [S]
Display Content
[1]
Device No.
[2]
Contact image
ON:
OFF: Blank
[3]
Reset image
ON:
OFF: Blank
[4]
Count direction display
UP count:
DOWN count: Blank
(32-bit up/down counter and high-speed counter only)
[5]
Current value
[6]
Setting value
*1
Display Content
[1]
Device No. at beginning of line.
Input (X) and output (Y): 8 points per line.
Auxiliary relay (M), special auxiliary relay (M), and state (S): 10 points per line.
[2]
ON/OFF status
ON: Last digit of device No..
OFF: " . ".
0
C0 R
0
01
C0 to C199
[1]
[5]
[6]
0
U
C0 R
1
-
C200 to C255
[3]
[4]
[5]
[5]
[6]
02
S
[2]
[2] [3]
[1]
NC
VC
NC
VC
CS
C
X000 01234 . . .
X010 . . .34567
X020 012 . . .67
X030 . . . . .56 .
[2]
[1]
M0
M10 3..67
M20
M30
[2]
....2
.45. .89...
.45. .8901 .
3..67. .012
[1]

Table of Contents

Other manuals for Mitsubishi FX3G Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3G Series and is the answer not in the manual?

Mitsubishi FX3G Series Specifications

General IconGeneral
ModelFX3G Series
Power SupplyAC 100-240V or DC 24V
Program Capacity32, 000 steps
Execution Speed0.21 µs/basic instruction
Communication OptionsRS-422, USB, Ethernet
Expansion ModulesAnalog, digital, communication
Programming LanguageLadder Logic, Instruction List
Built-in FunctionsHigh-speed counters, pulse output
Analog I/OAvailable via expansion modules