V5A51 -
Transfer Case Adapter
23E-4-2
"
B
A
SEALING CAP INSTALLATION
1. Press the sealing caps into the dimensions shown in
the illustration so that they are not slanted.
2. Apply sealant as shown in the illustration.
Specified sealant:
3M
TM
AAD part No. 8672 or equivalent
"
C
A
PARKING SPRAG SPRING INSTALLATION
Attach the end of the spring to the position shown in the
illustration.
AddedPWEE8920-I
E
Mar. 2000Mitsubishi Motors Corporation
1.5 mm
Sealing cap
1.5 mm