Description of the unit
24 Operating instructions
3.5.2 Loading capacity
Version Per shelf maximum (kg) Per cooking zone
maximum (kg)
610 15 30
3.6 Standard setting values
3.6.1 Temperature standard setting
The adjustment range for the cooking zone temperature depends on
the cooking mode.
Cooking mode Standard value
(°C)
Adjustment
range (°C)
Alteration
increments (°C)
Steaming 100 30 - 130 1
Combisteaming 150 30 - 250 1
Convection 180 30 - 300 1
Regeneration 50 30 - 180 1
3.6.2 Core temperature standard setting
The adjustment range for the core temperature depends on the
cooking mode.
Cooking mode Standard value
(°C)
Adjustment
range (°C)
Alteration
increments (°C)
Steaming 70 0 - 99 1
Combisteaming 70 0 - 99 1
Convection 70 0 - 99 1
Regeneration 50 0 - 99 1
3.6.3 Cooking zone humidity standard setting
The adjustment range for the cooking zone humidity depends on the
cooking mode.
Cooking mode Standard value
(%)
Setting range
(%)
Change increments
(%)
Steaming 100 90 - 110 90 - 100 - 110
Combisteaming 90 20 - 100 20 - 40 - 70 - 90 - 100
Convection 100 0 - 100 0 - 25 - 50 - 75 - 100
Regeneration 100 0 - 100 0 - 25 - 50 - 75 - 100
4127003--0ABBE-E