Table 2.10 HVI Connector Assignments
Connector Assignment Description
J3 UTL Up Terminal Limit input, lighted when switch is closed
J3 USL1 Up Slow Limit 1 input, lighted when switch is closed
J3 USL2 Up Slow Limit 2 input, lighted when switch is closed
J3 DTL Down Terminal Limit input, lighted when switch is closed
J3 DSL1 Down Slow Limit 1 input, lighted when switch is closed
J3 DSL2 Down Slow Limit 2 input, lighted when switch is closed
J3 UETS Up Emergency Terminal Switch input, lighted when switch is closed
J3 DETS Down Emergency Terminal Switch input, lighted when switch is closed
J4, MCE 2LS 2LS 110VAC input, MCE
J4, MCE 2LS 2LS 110VAC input, MCE
J4, MCE PM Motor Contactor power, MCE
J4, MCE BR Brake Contactor power, MCE
J5, MCE 2 2 bus, 110VAC input, MCE
J5, MCE 2 2 bus, 110VAC input, MCE
J5, MCE 2MV 2MV bus, 110VAC input, MCE
J5, MCE 1 Common, MCE
J5, MCE 1 Common, MCE
J6 USE/BR Up Slow Enable output (pulls to ground when valve is activated), active when
power is on (110VAC)/BR is brake contactor output for traction application
J6 UFE/PM Up Fast Enable output (pulls to ground when valve is activated), active when
power is on (110VAC/PM is motor contactor output for traction application
J6 DFE/EB1 Down Fast Enable output (pulls to ground when valve is activated), active when
power is on (110VAC)/EB1 is emergency brake output for traction
J6 DSE/EB2 Down Slow Enable output (pulls to ground when valve is activated), active
when power is on (110VAC)/EB2 is emergency brake output for traction
J6 RG Rope Gripper (Not Used in hydraulic applications)
J7, MCE 2LS 2LS bus, 110VAC
J7, MCE 2MV 2MV bus, 110VAC
J7, MCE GOV Governor switch
J7, MCE 1 Common
J7, MCE 2 110VAC
J8, MCE RG Rope Gripper
J8, MCE EB12 Emergency Brake
J8, MCE EB1 Emergency Brake
J8, MCE EB2 Emergency Brake
J8, MCE EB3 Emergency Brake
J8, MCE EB4 Emergency Brake
J8, MCE ESC Emergency stop switch bypass
J9 GOV Governor, lighted when overspeed switch is closed
J9 SAFH Safety string Hoistway, lighted when string is made (110VAC)
J9 SAFC Safety string Car, lighted when string is made (110VAC)
J9 ESC Emergency Switch Car, lighted when switch is closed (110VAC)
J9 2 2bus 110VAC