Chapter 4
| System Management Commands
System Status
– 86 –
■
Users (names and access levels)
■
VLAN database (VLAN ID, name and state)
■
Multiple spanning tree instances (name and interfaces)
■
Interface settings and VLAN configuration settings for each interface
■
IP address for management VLAN
■
Any configured settings for the console port and Telnet
Example
Refer to the example for the running configuration file.
Related Commands
show running-config (84)
show system This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
◆ The POST results should all display “PASS.” If any POST test indicates “FAIL,”
contact your distributor for assistance.
◆ The number of fans provided: EX-3524 - 2, EX-3548 - 3
Example
Console#show system
System Description : EX-3524 Managed POE/POE+ Switch
System OID String : 1.3.6.1.4.1.388.19.101
System Information
System Up Time : 0 days, 5 hours, 45 minutes, and 35.48 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 70-72-CF-95-DC-46
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Disabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
System Fan:
Unit 1
Fan 1: OK Fan 2: OK
POST Result:
Console#