8 ADJUSTMENTS
74 Rev. 01/2015
Following statuses are possible:
READY
The ignition controller is ready for operation.
FIRING
The ignition controller is firing.
NO MPU
No input signal detected.
TOO SLOW
The speed is too slow (less than 60 crankshaft revolutions or 30 camshaft
revolutions). This can be caused by an incorrect sequence number, a wrong trigger
disc or a weak pickup signal.
WAIT FOR 0
The ignition controller is waiting for engine standstill.
SECURITY ON
The Start/Stop input is closed.
OVERSPEED ERR
The defined overspeed level was exceeded.
CAM MPU ERROR
Errors with the pickup signal were detected.
OUTPUT FAILURERATE EXCEEDS
The defined misfire rate for the indicated output was exceeded.
LOW VOLTAGE
The supply voltage has fallen below 10 V.
CHECKSUM ERR
A loss in voltage occurred in programming mode, which led to a failure. The unit
must be re-parameterized.