3-1
Chapter 3,
Specifications
Table 3-1. Performance Specifications
GAS TYPES Combustibles, Oxygen & Toxics
TEMPERATURE TOXICS & OPERATING 0 to 40°C (32 to +104°F)
RANGE OXYGEN RANGE
*EXTENDED -20 to +50°C (-4 to +122°F)
RANGE
OPERATING 0 to +30°C (32 to +86°F)
RANGE NH
3
*EXTENDED -10 to +40°C (+14 to +104°F)
RANGE NH
3
,
Cl
2
, ClO
2
Calibrate within operating range
CATALYTIC SINGLE & -40 to +60°C (-40 to +140°F)
COMBUSTIBLES DUAL
MODULES
IR SINGLE & -40 to +60°C (-40 to +140°F)
COMBUSTIBLES DUAL
MODULES
STORAGE -40 to +70°C (-40 to +158°F)
TEMPERATURE or limits of the sensor
RANGE
DRIFT ZERO DRIFT Less than 5%/year, typically
SPAN DRIFT Less than 10%/year, typically
NOISE Less than 1% FS
*Extended Range = The sensor may not meet all of the accuracy parameters listed.