1. POST Error Message
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
136
Chapter 3 Appendix
(3/4)
Error Message Description Action
B23A PCI Slot 1A - PCIe Link
Width Error
(Express5800/R110f-1E)
A PCIe bus link width error was
detected in PCI slot 1A.
B23B PCI Slot 1B - PCIe Link
Width Error
(Express5800/R110f-1E)
A PCIe bus link width error was
detected in PCI slot 1B.
B261 Onboard LAN 1 - PCIe Link
Speed Error
A PCIe bus link speed error was
detected on the onboard LAN1
port.
B262 Onboard LAN 2 - PCIe Link
Speed Error
A PCIe bus link speed error was
detected on the onboard LAN2
port.
B271 PCI Slot 1 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
A PCIe bus link speed error was
detected in PCI slot 1.
B272 PCI Slot 2 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
A PCIe bus link speed error was
detected in PCI slot 2.
B273 PCI Slot 3 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
A PCIe bus link speed error was
detected in PCI slot 3.
B274 PCI Slot 4 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
A PCIe bus link speed error was
detected in PCI slot 4.
B27A PCI Slot 1A - PCIe Link
Speed Error
(Express5800/R110f-1E)
A PCIe bus link speed error was
detected in PCI slot 1A.
B27B PCI Slot 1B - PCIe Link
Speed Error
(Express5800/R110f-1E)
A PCIe bus link speed error was
detected in PCI slot 1B.
Contact your sales representative.
C010
The error occurred during
temperature sensor
reading
An error occurred while reading
the temperature sensor.
Contact your sales representative.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
A cooling fan has a failure or is
clogged by dusts. Contact your sales
representative.
C020 The error occurred during
voltage sensor reading.
An error occurred while reading
the voltage sensor.
C021 System Voltage out of the
range.
A system voltage abnormality
was detected.
C040 SROM data read error
SROM data reading error
C061 1st SMBus device Error
detected.
An error occurred in the 1st SM
Bus.
C062 2nd SMBus device Error
detected.
An error occurred in the 2nd SM
Bus.
C063 3rd SMBus device Error
detected.
An error occurred in the 3rd SM
Bus.
C064 4th SMBus device Error
detected.
An error occurred in the 4th SM
Bus.
C065 5th SMBus device Error
detected.
An error occurred in the 5th SM
Bus.
C066 6th SMBus device Error
detected.
An error occurred in for the 6th
SM Bus.
C067 7th SMBus device Error
detected.
An error occurred in the 7th SM
Bus.
C068 8th SMBus device Error
detected.
An error occurred in the 8th SM
Bus.
Contact your sales representative.
C103 BMC core hardware
failure.
BMC device (chip) error
C104 BMC IBF or OBF check
failed.
Accessing the BMC address
failed.
Turn off the power, disconnect the
server from the outlet, wait for at least
30 seconds, and restart the server. If
the error occurs again, contact your
sales representative.
C105 BMC SEL area full.
No memory to write the system
event log.
Run the offline tools by pressing <F4>
key and delete the event logs.