1. System BIOS
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
77
Chapter 2 Useful Features
(2/2)
Option Parameter Description
Assert NMI on SERR
Disabled
[Enabled]
Enables or disables the feature to detect PCI
SERR.
FRB-2 Policy
[Retry 3 Times]
Disable FRB2 Timer
Always Reset
Specifies how to operate when FRB level 2
errors occur.
Boot Monitoring
[Disabled]
5-60 minutes
Enables or disables the boot monitoring
feature and specifies the timeout setting.
To use this feature, install NEC ESMPRO
Agent on Windows. If starting up an OS on
which it is not installed, disable this feature.
Boot Monitoring Policy
[Retry 3 times]
Always Reset
Specifies the processing to be done when
time-out was enforced during boot
monitoring. This is configurable only if Boot
Monitoring has been enabled.
Retry 3 times resets the server upon the
timeout and attempts to boot OS up to three
times.
Always Reset retries booting the OS
repeatedly.
Thermal Sensor
Disabled
[Enabled]
Enables or disables the thermal sensor
monitoring. If this option is set to Enabled
and when abnormal temperature is detected,
the system stops at the end of POST.
Check previous System Config
[Disabled]
Enabled
If this option is set to Enabled and the
system configuration differs from the
previous boot, the system waits for user’s
intervention before booting.
BMC IRQ
(Express5800/T110f-E)
[Disabled]
IRQ 11
Specifies whether to assign an interrupt line
to the BMC.
Post Error Pause
Disabled
[Enabled]
Specifies whether to stop the POST once at
the end of POST if an error occurs during the
POST.
Memory Error
Halt
[Boot]
Specifies whether to stop operation at the
end of POST processing if a memory
resource error occurred while executing
POST.
This option is enabled if POST Error Pause
in the Server menu is enabled.
Even if this option is set to Boot, operation
stops at the end of POST if errors occurred
for all resources.
Power Switch Inhibit
[Disabled]
Enabled
Enables or disables the power switch inhibit
feature.
CLI SETUP
[Disabled]
Enabled
Specifies whether to use Command Line
Interface (CLI).
Enabled : SETUP is run by CLI instead of
the menu operation. To switch back to the
meu operation, set this option to Disabled on
CLI.

Table of Contents

Other manuals for NEC Express 5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Express 5800 Series and is the answer not in the manual?

NEC Express 5800 Series Specifications

General IconGeneral
BrandNEC
ModelExpress 5800 Series
CategoryServer
LanguageEnglish

Related product manuals