Configuring group power capping
Prerequisites
An iLO license that supports this feature is installed.
Each member of the selected iLO Federation group has granted the Configure iLO Settings
privilege to the group.
Procedure
1. Click iLO Federation in the navigation tree, and then click the Group Power Settings tab.
2. Select a group from the Selected Group menu.
Changes you make on this page affect all systems in the selected group.
3. Select the Enable power capping check box.
4. Enter the Power Cap Value in watts, BTU/hr, or as a percentage.
The percentage is the difference between the maximum and minimum power values. The
power cap value cannot be set lower than the server minimum power value.
5. Optional: When values are displayed in watts, click Show values in BTU/hr to change the
display to BTU/hr. When values are displayed in BTU/hr, click Show values in Watts to
change the display to watts.
6. Click Apply.
Group power capping considerations
The Group Power Settings feature enables you to set dynamic power caps for multiple servers
from a system running the iLO web interface.
When a group power cap is set, the grouped servers share power to stay below the power