iLO AlertMail
iLO AlertMail enables you to configure iLO to send alert conditions detected independently of
the host operating system to a specified email address. iLO mail alerts include major host system
events.
Some email service providers establish filters and rules to block problem emails such as spam,
commercial content, and unwanted volume. These tools might block the receipt of messages
generated by iLO. These email services are not suitable for receiving iLO AlertMail messages.
Sample of AlertMail
Enabling AlertMail
Prerequisites
• An iLO license that supports this feature is installed.
• Configure iLO Settings privilege
Procedure
1. Click Management in the navigation tree, and then click the AlertMail tab.
2. Set the Enable iLO AlertMail option to enabled.
3. Enter the following information:
• Email Address
• Sender Domain
• SMTP Port
• SMTP Server
4. Optional: To send a test message to the configured email address, click Send Test AlertMail.
This button is available only when AlertMail is enabled.
5. To save the changes, click Apply.
Subject: NEC iLO AlertMail-280: (CAUTION) System Fan Removed (Fan 4, Location System)
From: =iLO hostname < hostname.example.com@example.com>
To: mailreceiver@example.com
-------------------------------------------------------------------------------------------------------------------------------------------------
---
EVENT (15-Aug-2017 00:46): System Fan Removed (Fan 4, Location System)
Integrated Management Log Severity:CAUTION
iLO URL: https://hstname.example.com
iLO IP: https://172.16.0.1
iLO Name: hstname
iLO firmware: 1.10 Jun 07 2017
Server Model: Express5800/R120h-2M
System ROM: U30 06/14/2017 Server UUID: 01234567-89AB-CDEF-0123-4367890ABCDE
PLEASE DO NOT REPLY TO THIS EMAIL. For more details about NEC iLO technology, visit: jpn.nec.com/express/