163
Over Temperature Failure
Input Voltage Lost
Fan Failure
High Input A/C Warning
Low Input A/C Warning
High Output Warning
Low Output Warning
Inlet Temperature Warning
Internal Temperature Warning
High Vaux Warning
Low Vaux Warning
Mismatched Power Supplies
HotplugWhether the power supply bay supports swapping the power supply when the
server is powered on. If the value is Yes, and the power supplies are redundant, the power
supply can be removed or replaced when the server is powered on.
ModelThe power supply model number.
SpareThe spare power supply part number.
Serial NumberThe power supply serial number.
CapacityThe power supply capacity (watts).
FirmwareThe installed power supply firmware version.
Smart Storage Battery details
The following details are displayed on servers that support the Smart Storage Battery.
IndexThe battery index number.
PresentWhether a battery is installed. The possible values are OK and Not Installed.
StatusThe battery status. The possible values are OK, Degraded, Failed, or Other.
ModelThe battery model number.
SpareThe part number of the spare battery.
Serial NumberThe battery serial number.
CapacityThe battery capacity.
FirmwareThe installed battery firmware version.
Power monitoring
iLO monitors the power supplies in the server to ensure the longest available uptime of the
server and operating system. Brownouts and other electrical conditions might affect power
supplies, or AC cords might be unplugged accidentally. These conditions result in a loss of
redundancy if redundant power supplies are configured, or result in a loss of operation if
redundant power supplies are not used. If a power supply hardware failure is detected or the AC
power cord is disconnected, events are recorded in the IML and LED indicators are used.