229
System Log download.
• Valid FAT32 partition table.
• Not read-protected.
• Not bootable.
Mass storage devices are not supported on servers that do not have a NAND.
USB Ethernet adapters
The iLO Service Port supports USB Ethernet adapters that contain one of the following chips by
ASIX Electronics Corporation:
• AX88772
• AX88772A
• AX88772B
• AX88772C
Sample text file for Active Health System Log download through iLO Service
Port
When you use the iLO Service Port to download the Active Health System Log, you create a text
file called command.txt and save the file to a supported USB device. When you connect the
USB device to a server, the command.txt file runs and downloads the log file.
command.txt file template
Use the following example as a template for your command.txt file:
{
"/ahsdata/" : {
"POST" : {
"downloadAll" : "0",
"from" : "2016-08-25",
"to" : "2016-08-26",
"case_no" : "ABC0123XYZ",
"UserName" : "my_username",
"Password" : "my_password"
}
}
}
command.txt file parameters
You can customize the following values:
• downloadAll—Controls the download scope. To download the log for a range of dates,
enter 0. To download the entire log, enter 1.
• from—The start date when you download the log for a range of dates.
• to—The end date when you download the log for a range of dates.
• case_no (optional)—The case number for an open support case. This value can be up to 14
characters long. If you enter this value, it is included in the downloaded file.
• UserName—If iLO is configured to require authentication for iLO Service Port actions on
mass storage devices, enter an iLO account user name. A user name is not required when