2. At the bottom of the Directory page, click Test Settings.
iLO displays the results of a series of simple tests designed to validate the directory settings.
After your directory settings are configured correctly, you do not need to rerun these tests.
The Directory Tests page does not require you to log in as a directory user.
3. In the Directory Test Controls section, enter the DN and password of a directory
administrator in the Directory Administrator Distinguished Name and Directory
Administrator Password boxes.
NEC Corporation recommends that you use the same credentials that you used when
creating the iLO objects in the directory. iLO does not store these credentials; they are used
to verify the iLO object and user search contexts.
4. In the Directory Test Controls section, enter a test user name and password in the Test
User Name and Test User Password boxes.
5. Click Start Test.
Several tests begin in the background, starting with a network ping of the directory user by
establishing an SSL connection to the server and evaluating user privileges.
While the tests are running, the page refreshes periodically. You can stop the tests or
manually refresh the page at any time.