– 87 –
CHAPTER 4 OFFICE DATA DESIGN
CDN6 (TCL) = 4 (Tie Line)
CDN28 (ANS) = 0 (Access to announcement trunk is controlled by the current operation
(Timer Control))
= 1 (Answer and Release Timings are determined by DAT itself or the
external announcement equipment)
STEP 3: ATRK- Assign Trunk data for Announcement Trunk.
STEP 4: AADT- Assign Announcement/Dictation Trunks.
TYPE: 1 = Announcement Trunk
NO: Announcement number (1~58)
D: 1 = Disconnect Timer is available
CP: Announcement Connection Pattern Note 2
0 = Multi connection
1 = Single connection
MSGT: Message Timer (2-120 sec.) Note 3
Assign 16 sec./32 sec./60 sec. in the case of PA-4DATA.
WAIT: Waiting Timer (2-30 sec. 2 sec. increments) Note 2
RT: RT No.
TRK: TRK No.
STEP 5: MBTK/MBRT-Cancel the make busy status.
STEP 6: ARRC- Make the tandem connection between the announcement route and ACD route allow
Note: For more details of DAT card, see Installation Manual.
Note 1: The announcement service is provided in FCCS network, “0” is assigned in SYS1, INDEX449, b2.
Note 2: “CP” and “WAIT” are available when SYS1, INDEX449, b2=1.
Note 3: “MSGT” is not available when SYS1, INDEX449, b2=1. (Normally assign “0” with that data program-
ming)