– 362 –
CHAPTER 8 SYSTEM MAINTENANCE
2. MAINTENANCE
2.1 Daily Maintenance
The daily maintenance of the ACD System consists of the following checking.
Checking if the following system messages related to ACD system is displayed.
4-R “TCP/IP Link Failure”
5-Q “ACD-MIS LOCK UP”
6-H “Bad Call Notification”
26-V “LAN Interface Error Report”
26-Y “Standalone Mode Set Notification”
26-Z “Standalone Mode Release Notification”
2.1.1 The Relationship between System Messages and Lamp Indications
When the system has detected a fault, the corresponding system message is given out and, at the same time, the
related lamp on the TOPU illuminates.
Table 8-1 shows the relationship between system messages and lamp indications.
Table 8-1 System Messages and Lamp Indications on the TOPU
SYSTEM MESSAGE LAMP ON THE TOPU
REMARKS
NO. NAME MJ MN SUP NON
4-R TCP/IP Link Failure ×
5-Q ACD-MIS LOCK UP ×
6-H Bad Call Notification ×
26-V LAN Interface Error Report ×
26-Y Standalone Mode Set Notification ×
26-Z Standalone Mode Release Notification ×