CHAPTER 4 OFFICE DATA DESIGN
2.1 System Data Assignment
ACD system basic data is as follows. For details of system data, refer to Data Programming Sheets.
Basic ACD data
STEP 1: ASYD - SYS1, INDEX2: 01 Hex (ACDP is mounted)*
INDEX31: 04 Hex*
INDEX70, b6: 1 (Announcement Trunks used for delay announcements/night
announcements is provided)
INDEX61, b5: 0 (UCD Call Waiting Display is out)
Note: UCD Call Waiting
Display service cannot be used for ACD System.
INDEX79, b6: 0 (ACD/OAI in service)*
INDEX80, b3: 0 (Static ACD messages (Break, Ready, etc.) is displayed on
the top line of the LCD)
INDEX89, b3: 0/1 (CPU ACT/STBY changeover is not in service/in service)*
INDEX207, b0: 1 (ACDP SYS0 is mounted)
Note 1*
INDEX207, b1: 0/1 (ACDP SYS1 is not mounted/mounted)
Note 1*
Note 1: b0=1, b1=0 for Single ACDP system/b0=1, b1=1 for Dual ACDP system.
INDEX241, b2: 1 (Call Processing Event Notification)*
INDEX241, b3: 1 (Details of SCF Error Notification)
INDEX448, b1: 1 (ACDP specifications UP)
STEP 2: ASYDL - SYS1, INDEX513: 01 Hex (LDM usage)*
INDEX515~518: IP address (Hex) for Telephony Server over External LAN
Note 5*
INDEX519~522: Subnet Mask (Hex) for Telephony Server over External LAN
Note 5*
INDEX523~526: Default Gateway Address for External LAN
Note 5*
Gateway Address (IP Address of Router) of Network connect-
ing Telephony Server
INDEX864, b0: =1 (Built-in IP, ACDP is used)* (When Built-in IP/ACDP is
used, Index 864, b4 must be assigned as data “1”, and Index
864, b5 must be assigned as “0.”)
INDEX864, b1: Output the system message when TCP-IP connection is normal-
ly disconnected*
0/1=Effective/Ineffective
INDEX864, b4: Assign number of ports of Status Monitoring for terminal
(SMFN).
0/1=2 ports/8 ports (Normal Setting)
Note 2 Note 3
INDEX864, b5: Clear SMFN when the FCCS Link is down.
0/1=Clear (Normal Setting)/Not Clear
Note 2 Note 4
INDEX867, b3: (For countries except North America) Improvement of SCF6
Request for Monitor Connection.
0/1 = Out of service/In service
Note 2:
This identical data value must be assigned to all nodes.
Note 3: When “Status Monitor Facility Request (SMFR), FN=126” is used, always assign 0 (2 ports).
Note 4: Although this data is valid only when INDEX864 b4=1 (8 ports), this bit must be assigned as data “0” when
INDEX864 b4=0 (2 ports).
Note 5:
This data is assigned by ADTM. The assigned ADTM data is automatically written into the System Data.