EasyManua.ls Logo

NEC UNIVERGE SV7000 - MULTILINE APPEARANCE

NEC UNIVERGE SV7000
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 65 –
CHAPTER 4 OFFICE DATA DESIGN
Note 2: Monday’s table starts from “00:02”. The others start from “00:00”.
Example:
Week Schedule
Week schedule is specified by the following combination.
Time tables for ACD call processing patterns can be programmed per a day of week.
CCV Index 79 (CCVNO = 79)
Command: ACDPLT
Command: ACDWS
Week schedule No. 5 (SCH = 5)
WEEK
Mon.
Fri.
HOUR/MINUTE
01 : 00
09 : 00
12 : 00
13 : 00
17 : 00
CCVNO
70
71
78
71
79
WEEK
Sat.
HOUR/MINUTE
00 : 00
09 : 00
17 : 00
CCVNO
70
72
79
CCV Index 70 (CCVNO = 70)
Command: ACDCCV
Call processing
pattern in Night
CCV Index 71 (CCVNO = 71)
Call processing
pattern in Day
CCV Index 72 (CCVNO = 72)
Call processing
pattern for Saturday
in Day
CCV Index 78 (CCVNO = 78)
Call processing
pattern in Lunch time
Call processing
pattern after Work
CCV/W
Weekly Schedule No.
(WEEKNO)
1 (Week Schedule) 5
Note: CCV = Call Control Vectors
Monday’s table starts from“00:02”. Others start from “00:00”.
Mon.
CCV Index 70
Fri.
CCV Index 71
CCV Index 78
CCV Index 71
CCV Index 79
00 : 02/00 : 00
09 : 00
12 : 00
13 : 00
17 : 00
24 : 00
Sat.
CCV Index 70
CCV Index 72
CCV Index 79
00 : 00
09 : 00
17 : 00
24 : 00

Table of Contents

Other manuals for NEC UNIVERGE SV7000

Related product manuals