Configure Switching
129
S350 Series 8-Port Gigabit Ethernet Smart Managed Pro Switch Models GS308T and GS310TP
5. Select Switching > Auto-VoIP > OUI-based > Port Settings.
6. Select one or more interfaces by taking one of the following actions:
• T
o configure a single interface, select the check box associated with the port, or type
the port number in the Go To Interface field and click the Go button.
• T
o configure multiple interfaces with the same settings, select the check box
associated with each interface.
• T
o configure all interfaces with the same settings, select the check box in the heading
row.
7. From the Auto V
oIP Mode menu, select Disable or Enable.
Auto-VoIP is disabled by default.
8. Click the Apply button.
Your settings are saved.
The Operational Status field displays the current operational status of an interface.
Manage the OUI Table
Device hardware manufacturers can include an OUI in a network adapter to help identify a
hardware device. The OUI is a unique 24-bit number assigned by the IEEE registration
authority. The switch comes preconfigured with the following OUIs that identify the IP phone
manufacturer:
• 00:01:E3: SIEMENS
• 00:03:6B: CISCO1
• 00:12:43: CISCO2
• 00:60:B9: NITSUKO
• 00:D0:1E: PINTEL
• 00:E0:75: VERILINK
• 00:E0:BB: 3COM
• 00:04:0D: A
VAYA1
• 00:1B:4F: A
VAYA2
You can select an existing OUI or add a new OUI and description to identify the IP phones on
the network.