EasyManua.ls Logo

NETGEAR GS310TP

NETGEAR GS310TP
351 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configure Switching
170
S350 Series 8-Port Gigabit Ethernet Smart Managed Pro Switch Models GS308T and GS310TP
8. From the Keep Alive menu, select Enable or Disable to specify whether keep-alives are
enabled on an interface.
The default is Disable.
9. From the RX Action menu, select the action that occurs when the switch detects a loop on
an interface:
Log.
The switch logs a message.
Disable.
The switch disables the interface. This is the default action.
Both.
The switch both logs a message and disables the interface.
10. Click the Apply button.
Your settings are saved.
11. Click the Clear button to clear all the statistics in the table.
12. Click the Update button to update the page to show the latest information.
The following table describes the nonconfigurable information displayed on the page.
Table 40. L2 Loop Protection Interface Information
Field Description
Loop Detected Shows whether a loop is detected on the interface. If the interface is disabled and then
reenabled, the status changes to No again.
Loop Count The number of packets that were received after the loop was detected.
Time Since Last Loop The time that elapsed since the loop was detected.
Port Status The status of the interface (Enabled, Disabled, or D-Disabled, which stands for
diagnostically disabled).