EDH0162En1040 – 06/99 3.84
MM4005 NP — Set decimal digits number of position display
Usage IMM PGM MIP
Syntax xxNPnn or xxNP?
Parameters
Description xx
[int] — Axis number.
nn [int] — New value of displayed resolution.
Range xx — 1 to 4.
nn
— 1 to MDR (Maximum Display Resolution).
Units xx — None.
nn — None.
Defaults xx Missing: Error B.
Out of range: Error B.
Floating point: Error A.
nn Missing: Default value of actual unit.
Out of range: Error C.
Description This command sets new value of number of digits after the decimal point of
on screen displayed position values. The MDR value, dependant on the
actual unit, is described below:
Unit mm µm In mIn µIn Dg Gr Rad mRd µRd Inc
MDR 63741666310
To restore the default value of the actual unit, use xxNP.
NOTE
This command returns an error code if the actual unit is Inc.
Returns
If the sign “?” takes place of the nn value, this command reportes the num-
ber of decimal digits after the decimal point of on screen displayed posi-
tion values.
Errors A — Unknown message code.
B — Incorrect axis number.
C — Parameter out of limits.
D — Unauthorized execution.
Rel. Commands SF — Set axis mechanical motion device.
SN — Set axis displacement units.
Example
1SFUTM100CC0.5HA | Set mechanical driver to UTM100CC0.5HA.
1SNmI. | Set unit to mInch.
1NP4 | Set position displayed precision to 4.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com