XPS Unified Programmer’s Manual
7.2.1.291 PositionerTimeFlasherDisable
Name
PositionerTimeFlasherDisableDisables the time flasher mode.
Input tests
- Refer to section 7.1: “Input Tests Common to all XPS Functions”.
- Checks the positioner type (must not be a secondary positioner): (-8)
Description
This function disables the time flasher mode. The time flasher mode is a trigger output
per axis that can be either configured to output distance spaced pulses or time spaced
pulses. The output pulses are accessible from the PCO connector at the back of the XPS
controller.
For a more thorough description of the position compare output, please refer to the XPS
User’s manual, section named Triggers/Position Compare Output.
Prototype
int PositionerTimeFlasherDisable(
int SocketID,
char * FullPositionerName
)
Input parameters
SocketID int Socket identifier gets by the
“TCP_ConnectToServer” function.
FullPositionerName char * Positioner name.
Output parameters
None.
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
0: No error.
-8: Wrong object type for this command.
EDH0373En1023 01/18 434

Table of Contents

Other manuals for Newport XPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Newport XPS and is the answer not in the manual?

Newport XPS Specifications

General IconGeneral
Controller TypeMulti-axis motion controller
Power Supply24 VDC
Communication InterfaceEthernet
Programming LanguageC, C++, .NET, LabVIEW
Supported Motor TypesStepper
Operating System CompatibilityWindows
AxesUp to 8 axes