XPS Unified Programmer’s Manual
Input parameters
SocketID int Socket identifier gets by the
“TCP_ConnectToServer” function.
FullPositionerName char * Positioner name.
MinimumPosition double Minimum position (units).
MaximumPosition double Maximum position (units).
TimePeriod double Time period (seconds).
EnableState bool Enable time flasher state (true = enabled and
false = disabled).
Output parameters
None.
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
• 0: No error.
• -8: Wrong object type for this command.
• -17: Parameter out of range or incorrect.
• -22: Not allowed action.
• -24: Not available in this configuration (check hardware or configuration).
• -115: Function is not supported by current hardware.
EDH0373En1023 — 01/18 438