VRA53801-R.3609.A
- R4 ・ -
LS-50
5. Scanning time
・ Prescan preview time (When Standard PC is used):
Standard Positive lm 16 sec. or less
High concentrated lm: 120 sec. or less
・Main scanning time (USB2.0)(Same as 8/14 bits):
35-mm Positive 44 sec. or less
35-mm Netative 70 sec. or less
APS Positive 34 sec. or less
APS Negative 55 sec. or less
・Main scanning time (USB1.1):
35-mm Positive
8 bits: 90 sec. or less
14 bits: 150 sec. or less
・Thumbnail time:
SA-21 30 sec. or less
IA-20(S)
25-frames winding time 19 sec. or less
25-frames thumbnail time 120 sec. or less
40-frames winding time 25 sec. or less
40-frames thumbnail time 200 sec. or less
6. Image quality performance 2
・Negative lm reproducible density range
Under conditions of CMS off, γ=1, and 14 bits, output images should be scanned within the range from
the min. value is (0) to max. value (16383) of RGB.
・Gradation sequence
The lm with up to 2.4 density should be scanned accurately within ±0.1 of the difference between the
output density and ideal density.
Indistinctive tone jump