EasyManua.ls Logo

Nokia 616 - TF-4 Synthesizer; General Instructions for Synthesizer Troubleshooting

Nokia 616
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TFE-4/RV-1 Company Confidential
TF4 Technical Information Nokia Customer Care
Page 8b-60 Copyright © 2005 Nokia Corporation. Issue 2.0 Mar/2005
Company Confidential
TF-4 Synthesizer
There is only one PLL synthesizer generating frequencies for both Rx and TX and for all
two bands (EGSM900 and GSM1800). VCO frequency is divided by 2 or by 4 in Mjoelner
depending on which band is active.
General instructions for Synthesizer troubleshooting
Step 1: Setting up Phone and Phoenix
Start Phoenix Service Software
Open the FBUS connection
Select File /Scan Product (Ctrl-R)
Wait until phone information shows in the lower right corner of the screen.
Set operating mode to local mode
Activate RF-Controls
Select Maintenance/ Testing/ RF Controls
Wait until the RF Controls window pops up
Select: Band GSM 900 or GMS1800
Active unit RX
Operation mode Continuous
RX/TX Channel 37 or 700
The setup should now look like this:
Step 2: Doing the Measurement
Since VCO chamber is completely shielded, it is not easy to measure frequency of
3769.6MHz at the output of the VCO (G701) using a resistive probe and a spectrum ana-
lyzer. It is possible to measure tuning voltage at charge pump output (C710) easily. For
f
VCO
= 3769.6MHz the tuning voltage should be 2.3V
DC
.. 2.8V
DC
(Tuning sensitivity of
VCO is 240MHz/V typ.).
If this is not the case, then go to section 1.4 of this document for troubleshooting.