System Management
376
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
commit
Syntax commit
Context config>system>sync-if-timing
Description This command is required in order to save the changes made to the system synchronous
interface timing configuration.
external
Syntax external
Context config>system>sync-if-timing
Description This command enables the context to configure parameters for external timing via the port on
the CSM. This can be used to reference external synchronization signals.
input-interface
Syntax input-interface
Context config>system>sync-if-timing>external
Description This command enables the context to configure parameters for external input timing interface
via the port on the CSM.
impedance
Syntax impedance {high-impedance | 50-Ohm | 75-Ohm}
Context config>system>sync-if-timing>external>input-interface
Description This command configures the impedance of the external input timing port. The command is
only applicable to the 7705 SAR-8, 7705 SAR-H, and 7705 SAR-M.
Default 50-Ohm
Parameters high-impedance — specifies a high input impedance value
50-Ohm — specifies a 50 Ω input impedance value
75-Ohm — specifies a 75 Ω input impedance value