Basic System Configuration Guide System Management 
Edition: 01 3HE 11010 AAAC TQZZA 395
 
Context config>system>ptp>clock
Description This command configures the first priority value of the local clock. This value is used by the 
BMCA to determine which clock should provide timing for the network. It is also used as the 
advertised value in announce messages and as the local clock value in data set comparisons. 
When the profile command is set to g8275dot1-2014, the priority1 value is set to the default 
value of 128 and cannot be changed.
The no form of the command returns the configuration to the default value. 
Default 128
Parameters priority  — specifies the priority1 value of the local clock
Values 0 to 255
priority2
Syntax priority2 priority-value
no priority2
Context config>system>ptp>clock
Description This command configures the second priority value of the local clock. This value is used by 
the BMCA to determine which clock should provide timing for the network. It is also used as 
the advertised value in announce messages and as the local clock value in data set 
comparisons. 
When the profile command is set to g8275dot1-2014 and the clock-type is configured as 
ordinary slave, the priority2 value is set to the default value of 255 and cannot be changed.
The no form of the command returns the configuration to the default value.
Default 128
Parameters priority  — specifies the priority2 value of the local clock
Values 0 to 255 when the profile is configured as ieee1588-2008, or when 
the profile is configured as g8275dot1-2014 and the clock type is 
configured as ordinary master or boundary
profile
Syntax profile {g8275dot1-2014 | ieee1588-2008 | itu-telecom-freq}
no profile
Context config>system>ptp>clock