System Management
472
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
sync-if-timing
Syntax sync-if-timing
Context show>system
Description This command displays synchronous interface timing operational information.
Output The following output is an example of synchronous interface timing information, and Table 60
describes the fields.
Output Example
A:ALU-1# show system sync-if-timing
===============================================================================
System Interface Timing Operational Info
===============================================================================
System Interface Timing Operational Info
===============================================================================
System Status CSM A : Master Locked
Reference Input Mode : Non-revertive
Quality Level Selection : Disabled
Reference Order : bits ref1 ref2
Reference Input 1
Admin Status : down
Configured Quality Level : none
Rx Quality Level : unknown
Qualified For Use : No
Not Qualified Due To : disabled
Selected For Use : No
Not Selected Due To : disabled
Reference Input 2
Admin Status : down
Configured Quality Level : none
Rx Quality Level : unknown
Qualified For Use : No
Not Qualified Due To : disabled
Selected For Use : No
Not Selected Due To : disabled
Table 59 System Uptime Output Fields
Label Description
System Up Time The length of time the system has been up in days,
hr:min:sec format
Note: Some of the fields in the following output apply to the 7705 SAR-18 only.