EasyManua.ls Logo

Nokia 7705 - Page 70

Nokia 7705
538 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Usage
70
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
Parameters no-of-nodes-in-prompt — the maximum number of higher-level nodes displayed by
name in the prompt, expressed as a decimal integer
Values 0 to 15
Default 2
saved-ind-prompt
Syntax [no] saved-ind-prompt
Context environment
Description This command enables a saved indicator in the prompt. When changes are made to the
configuration file, a “*” appears in the prompt string indicating that the changes have not been
saved. When an admin save command is executed, the “*” disappears.
*A:ALU-48# admin save
Writing file to ftp://128.251.10.43/./sim48/sim48-config.cfg
Saving configuration .... Completed.
A:ALU-48
Default saved-ind-prompt
suggest-internal-objects
Syntax [no] suggest-internal-objects
Context environment
Description This command enables the suggestion of internally created objects while auto-completing in
the CLI.
Default no suggest-internal-objects
terminal
Syntax terminal
Context environment
Description This command enables the context to configure the terminal screen length and width for the
current CLI session. The terminal length and width cannot be configured for Telnet or SSH
sessions, as the correct display size is automatically negotiated.

Table of Contents

Other manuals for Nokia 7705

Related product manuals