Basic System Configuration Guide CLI Usage
Edition: 01 3HE 11010 AAAC TQZZA 75
---------------------------------------------------------------------------
Ing. Matches : 0
Egr. Matches : 0
ipv6
Syntax ipv6 ipv6-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context monitor>filter
Description This command enables IPv6 filter monitoring. The statistical information for the specified IPv6
filter entry is displayed at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified IPv6 filter. The
subsequent statistical information listed for each interval is displayed as a delta to the
previous screen output.
When the keyword rate is specified, the rate per second for each statistic is displayed instead
of the delta.
Monitor commands are similar to show commands, but only statistical information is
displayed. Monitor commands display the selected statistics according to the configured
number of times at the interval specified.
Parameters ipv6-filter-id — displays detailed information for the specified filter ID or filter name and
its filter entries
Values 1 to 65535 or filter-name (up to 64 characters)
entry-id — displays information for the specified filter entry ID
Values 1 to 65535
secondsconfigures the interval for each display in seconds
Values 3 to 60
Default 10
repeat — configures how many times the command is repeated
Values 1 to 999
Default 10
absolute — displays raw statistics, without processing. No calculations are performed
on the delta or rate statistics.
rate — displays the rate per second for each statistic instead of the delta