SETUP TOOL
LOAD FROM USB/COMPUTER
USE PREVIOUS FILE
CREATE NEW
Please select how to load a configuration file
ZONE TEMPERATURE
RUNTIME SETTINGS
ProBlue Flex OEM User’s Guide
28
Part 1129255_01
E 2020 Nordson Corporation
Defining Runtime Settings
The following sections detail the common operator tasks:
S Temperature settings
S Pressure settings
Defining Temperature Runtime Setting
There are two types of heated zones:
S Internal Zones: Tank and Manifold
S External Zones: Connected hoses and applicators
NOTES:
S By default, internal zones are enabled, and all external zones are
disabled.
S Internal zones (tank and manifold) cannot be disabled. You can only
change their set point temperatures.
S Although there are two internal zones (tank and manifold), changing one
internal zone automatically changes the other. You cannot have two
different internal zone set point temperatures.
Enabling/Disabling and Changing Zone Set Point
Temperatures
1. Log into your BBconn Cloud account, then do the following::
S Select SETUP TOOL - create or load a .NOR file
S Select SETUP TOOL | RUNTIME SETTINGS | ZONE
TEMPERATURE.
2. Do the following to continue:
S Press the to toggle (enable or disable) the zone.
S To change the set point temperature, select which zone you want to
change and enter the temperature set point your want.
S Enter a Global Set Point temperature to make all zones, (enabled or
disabled) the same set point temperature.
Zone Default Minimum Maximum
Internal Zones
(Tank/Manifold)
177_ C
(351
_ F)
40_ C
(100_ F)
204_ C
(400_ F)
External Zones
177_ C
(351_ F)
40_ C
(100_ F)
232_ C
(450_ F)
3. When done, press SAVE.
NOTE:
S You can change the default external zone names using either a PLC or
BBconn Cloud. Refer Modifying External Zone Names for more
information.