Defining Level Sensing Settings
This section of the manual details the following:
S Enable/Disable Low Level Alert and Settings
S Empty Stop
S Enable/Disable Lid Open Alert and Settings
Enabling/Disabling Low Level Alerts and Settings
Use the Level Sensing settings to fine-tune the low/empty adhesive
messaging.
TIP:
S You can also assign a system output for Tank Low and connect that to a
light tower.
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select SYSTEM SETTINGS | LEVEL/FILL.
2. Press the
to toggle (enable or disable) the Low Level Threshold
option. The default is Enabled.
3. Select Low Level Threshold, and enter a value representing the
percentage of adhesive left in the tank before receiving a low level
message. The default is 25%, the minimum is 10%, and the maximum is
30%.
4. When done, select SAVE.