Defining Pressure Runup Settings and Monitoring Alert
Settings
Use Pressure Runup to allow the system pressure to automatically adjust to
maintain the same adhesive output when the line speed changes. You can
optionally decide if you want to receive pressure alerts when the system
pressure, hydraulic or pneumatic exceeds the defined thresholds.
NOTES:
S The melter will go into an Alert condition only if the pressure meets or
exceeds the high/low thresholds for more than 10 seconds.
S You can change the pressure scaling from the System Settings |
Preferences. The default is pneumatic.
S The Set Point is a read-only, calculated value.
Pressure Runup General Settings
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select RUNTIME SETTINGS | PRESSURE. From the Main Pressure
Mode Selection, select Runup.
2. Press the
to toggle (enable or disable) the Pressure Settings
Range Alert option, which alerts you when the pressure is out of
tolerance. The default is Disabled.
3. Do the following to continue:
S Select, Full Scale Line Speed, and enter the required information.
Full Scale Line Speed is the line speed (in ft/min or m/min) when the
analog line speed inputs are at their maximum value (10V or 20 mA). This
must be defined in order to get accurate "output" settings.
Pressure Default Minimum Maximum
Meter/
Minute
100 1.5 300.2
Feet/
Minute
328 5 985