SETUP TOOL
LOAD FROM USB/COMPUTER
USE PREVIOUS FILE
CREATE NEW
Please select how to load a configuration file
PRESSURE
RUNTIME SETTINGS
ProBlue Flex OEM Users Guide
35
Part 1129255_01
E 2020 Nordson Corporation
S High Line Speed
Pressure Default Minimum Maximum
Meter/
Minute
30.5 1.5 300.2
Feet/
Minute
100 5 985
3. Select SAVE. Select Alert Threshold Settings to continue.
Pressure Runup Alert Threshold Settings
Enter the maximum/minimum pressure thresholds you want the system to
use before
receiving an alert alarm.
NOTES:
S An Alert Alarm is generated if the maximum or minimum pressure is out of
tolerance for more than 10 seconds.
S An “+” symbol appears next to the High Pressure Alert threshold setting
indicating the offset or delta from the Maximum Pressure Set Point Range
setting.
S An “-” symbol appears next to the Low Pressure Alert threshold setting
3indicating the offset or delta from the Minimum Pressure Set Point Range
setting.
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select RUNTIME SETTINGS | PRESSURE. From the Main Pressure
Mode Selection, select Runup.
2. Select Pressure Alert Threshold, and enter the following information:
S High Pressure:
Pressure Default Minimum Maximum
PSI 70 10 70
BAR 4.83 0.69 4.83
kPa 483 69 483
S Low Pressure:
Pressure Default Minimum Maximum
PSI 10 10 70
BAR 0.69 0.69 4.83
kPa 69 69 483
3. Select SAVE. Select Pressure Limits to continue.