ProBlue Flex OEM Users Guide
42
Part 1129255_01
E 2020 Nordson Corporation
Defining Setback Settings
Setback, also known as Standby, reduces the temperature by a user-defined
temperature offset from all enabled external zones.
There are three types of Setback options, including:
S Manual Enter/Exit Setback
S Automatic System Setback
S Manual Setback - Auto Exit Time
Manually Entering/Exiting Setback
S Press the Master control button to toggle On (enter) or Off (exit)
Setback.
NOTES:
S You can use the Setback Master control to exit out of any Setback mode.
S Upon exiting Setback mode, the melter status returns to Run (or Ready)
when all enabled zones are within 5 degrees of set point and the Master
Pump Control is switched On.