Defining System Temperature Settings
This section of the manual details the following Temperature System
Settings:
S SmartMelt (Melt-on-Demand only)
S Global (Temperature) Settings
S Setback
S Ready Delay
Defining SmartMelt Settings
SmartMelt is for Melt-on-Demand systems and allows the system to
automatically reduce the tank temperature by 17 C (31 F) if the fill system is
inactive for a user‐specified amount of time, thereby preventing adhesive
degradation. The system continues to maintain ready status until a fill signal
is generated again.
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select SYSTEM SETTINGS | TEMPERATURE.
2. Press the
to toggle (enable or disable) the SmartMelt option. The
default is Enabled.
3. Enter the Delay Time of fill inactivity before entering into SmartMelt
mode – reducing the temperature of tank. The default is 30 minutes,
minimum 15 minutes, and maximum is 60 minutes.
4. When done, select SAVE.
5. Refer to the following Temperature System Settings sections to
continue:
S Defining Global Temperature Settings
S Defining Setback Settings
S Defining Ready Delay Settings