Defining Temperature Setback
Use this setting to define the number of degrees by which all heated
components will be decreased (offset from current set point) when the
controller is placed into Heat Schedule and Manual/Automatic Setback.
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select SYSTEM SETTINGS | TEMPERATURE.
2. Select Temperature Setback, and enter the temperature offset for any
heated zone that you want to use when the melter is in setback. The
default is 50_ C (90_ F), the minimum is 5_ C (10_ F), and the maximum
is 60_ C (120_ F).
3. When done, select SAVE.
NOTE:
S Regardless of the defined setback temperature, the temperature set point
for any heated zone can only be reduced to 40_ C (100_ F).