SETUP TOOL
LOAD FROM USB/COMPUTER
USE PREVIOUS FILE
CREATE NEW
Please select how to load a configuration file
TEMPERATURE
SYSTEM SETTINGS
ProBlue Flex OEM Users Guide
44
Part 1129255_01
E 2020 Nordson Corporation
Defining Manual Setback - Auto Exit Time
Use Manual Setback - Auto Exit time to define the amount of time to
elapse before the melter exists Setback mode after you manually place it into
Setback.
Typically, you use this option when you want the melter to enter Setback for
shift changes and breaks, thereby preventing the adhesive from charring or
degrading.
1. Log into your BBconn Cloud account, then do the following:
S Select SETUP TOOL - create or load a .NOR file.
S Select SYSTEM SETTINGS | TEMPERATURE.
2. Press the
to toggle (enable or disable) the Manual Setback - Auto
Exit Time option. The default is Disabled.
3. Select Auto Exit Time Delay, and enter the amount of time you want the
melter to exit Setback. The default is 45 minutes, the minimum is 1
minute, and the maximum is 180 minutes.
4. When done, select SAVE.
NOTES:
S Press the Master control button to toggle Off (exit) Automatic
Setback.
S While in Setback, the System Status indicator is Blue.