ProBlue Flex OEM Users Guide
32
Part 1129255_01
E 2020 Nordson Corporation
6. Select Low Pressure Alert Threshold, then enter the amount of
pressure offset below the set point before the melter enters into an Alert
condition.
Pressure Default Minimum Maximum
PSI (-)10 from
set point
(-)5 from
set point
(-)70 from
set point
BAR
(-)0.69 from
set point
(-)0.34 from
set point
(-)4.83 from
set point
kPa (-)69 from
set point
(-)34 from
set point
(-) 483from
set point
7. Select High Pressure Alert Threshold, then enter the amount of
pressure offset above the set point before the melter enters into an Alert
condition.
Pressure Default Minimum Maximum
PSI (+)10 from
set point
(+)5 from
set point
(+)70 from
set point
BAR
(+)0.69
from set
point
(+)0.34
from set
point
(+)4.83
from set
point
kPa (+)69 from
set point
(+)34 from
set point
(+)483 from
set point
8. When done, press SAVE.
NOTES:
S The “+” symbol appears next to the High Pressure Alert threshold setting
indicating the offset or delta from the Maximum Pressure Set Point Range
setting.
S The “-” symbol appears next to the Low Pressure Alert threshold setting
indicating the offset or delta from the Minimum Pressure Set Point Range
setting.