Troubleshooting
6-4
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Alarm Number, Alarm Text and Optional Light Tower
(contd.)
Light tower colors
Alarm no. Status Green Yellow Red
25 Channel: Sensor input open or sensor broken
(Sensor = temperature sensor)
Hose/gun connected?
26 Channel: Sensor short-circuit
(Sensor = temperature sensor)
31 Motor or controller overtemperature
Ambient temperature too high
Fan cap / cooling section dirty
Pump blocked by foreign matter
Pump operates too sluggish
Material too cold
Check motor controller wiring and output voltage
40 Overpressure fault: Motor#, sensor#
Refer to Troubleshooting Tables in this section.
Light tower colors
Alarm no. Status Green Yellow Red
Status
display
Warning or fault (operator can choose)
When a Warning is issued, the operator must decide whether the situation is critical for the
application and action is required.
43 Safety valve open: Motor#
A Fault switches off the motors. As soon as the fault is corrected, the motor startup
protection is automatically activated.
43 Safety valve open: Motor#
Light tower colors
Alarm no. Status Green Yellow Red
Status
display
Shutdown
Shutdown turns the melter off (main contactor opens).
1 Main contactor / thermostat fault
Main contactor defective or open
Check wiring of main contactor and checkback
contact
Transformer temperature exceeded
Temperature exceeded
Continued...

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals