Nordson VersaBlue VB Series - Material Pressure too High; Material Pressure too Low; Incorrect Motor Rotation in Key-To-Line Mode

Nordson VersaBlue VB Series
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
6-19
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Material Pressure too High
Problem Possible Cause Corrective Action
Safety valve or pressure
control valve dirty and
thus blocked
Disassemble and clean or replace
Safety valve or pressure
control valve defective
Replace
Pressure control valve
set incorrectly
Set to default
Pneumatic safety valve
(option) pressurized with
too high pressure
Reduce pressure
Material Pressure too Low
Problem Possible Cause Corrective Action
Gear pump is worn Replace pump
Safety valve does not close
any more
Replace
Pressure control valve dirty
and thus clogged
Disassemble and clean or replace
Pressure control valve
defective
Replace
Pressure control valve set
incorrectly
Set to default
Pneumatic safety valve
(option) pressurized with
too low pressure
Increase pressure
Incorrect Motor Rotation in Key-to-line Mode
Problem Possible Cause Corrective Action
Line speed signal
fluctuates during
constant machine speed
Encoder defective or loose contact Replace
Drive element (e.g. belt) slips Eliminate slip