Technical Data
9-4
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Electrical Data (contd.)
Max. Melter Load (Without Accessories)
All data at 230 V
AC
V12 V25, V25H V50, V50H V100, V10H
With 1 motor
With 2 motors
With 3 motors
With 4 motors
6850 W
7650 W
8450 W
9250 W
7480 W
8280 W
9080 W
9880 W
12805 W
13605 W
14405 W
15205 W
21540 W
22340 W
23140 W
23940 W
Max. Load (Accessories)
Melter Types VB, VC, VW and VX
All data at 230 V
AC
V12 V25, V25H V50, V50H
*Max. 6 pairs
Total
Per hose/gun pair*
Per channel
10800 W
1800 W
1800 W
Melter Types VD, VE, VY and VZ
All data at 230 V
AC
V25, V25H V50, V50H V100, V10H
*Max. 8 pairs
Total
Per hose/gun pair*
Per channel
14400 W
4000 W
2000 W