Maintenance
5-4
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Preventive Maintenance (contd.)
Melter part
Activity Interval Refer to
Filling valve (option) Check control module
detection hole; replace
complete control module
if necessary
When excess material seeps out
of detection hole
(seals in inside worn)
5-20
Level and overflow
protection evaluators
Calibrate Only when evaluator or level
sensor is replaced
Section Repair
External Cleaning
External cleaning prevents impurities created during production from
causing the melter to malfunction.
CAUTION: Observe the unit’s Degree of Protection when cleaning (Refer
to section Technical Data).
CAUTION: Do not damage or remove safety labels. Damaged or removed
safety labels must be replaced by new ones.
Remove material residue only with a cleaning agent recommended by the
material supplier. Heat with an air heater if necessary.
Remove dust, flakes etc. with a vacuum cleaner or a soft cloth.
Nordson recommends the orange cleaning agent P/N 771 192 (12 spray
bottles, 0.5 liter each).
Control Panel
CAUTION: Set Screen cleaning (V20 in section Operation). This ensures
that no functions are unintentionally triggered by touching the screen.
Clean the insides of the plastic frame on the control panel front regularly
with a damp, soft cloth. Use caution to ensure that the surface is not
scratched or scoured, particularly when removing hard residue and abrasive
dust. Do not allow solvents to come into contact with the panel front;
solvents could corrode the plastic frame.