Troubleshooting
6-12
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Temperature Sensor Fault
Every temperature sensor is monitored.
Short-circuit-triggered
The temperature is lower than 10 °C (14 °F) for more than 5 seconds.
Triggered by Broken Sensor or Open Sensor Input
The temperature is higher than 305 °C (581 °F) for more than 5 seconds.
Automatic Reset
When the temperature remains above 10 °C (14 °F) or below 305 °C
(581 °F) for longer than 5 seconds, or when the defective sensor has been
replaced.
Level (Variable Measuring Points)
Warning Tank Overfilled
The warning is triggered as soon as the level has reached or exceeded 98%
for longer than 5 seconds. This is a fixed internal value.
Automatic Reset
When the level falls below 90 %.
Warning Tank Level Low
NOTE: This warning can only be triggered when the melter heater is on.
As soon as the level has fallen below the set value for longer than
5 seconds, a warning is triggered. The value for this warning is set in the
screen Level (Refer to Operation / Control Panel Overview / V13).
Automatic Reset
When the set value is exceeded.
Fault Tank Empty
The fault is triggered as soon as the level reaches or falls below 2 % for
longer than 5 seconds. This is a fixed internal value.
Automatic Reset
When the level exceeds 5 %.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals